APPENDIX B - CONFIGURATION EDITOR SYNTAX
ENG
104
Axel Technology srl
www.axeltechnology.com
; 3E PTYN
;
; for each Port.
;
; NOTE: For current port disable ALL services is not allowed.
; User can specify service ID (separated by comma) or
; simply type NONE or ALL for a global Enable/Disable.
;
; *** Current Port: Port 1 ***
[RDS_SETTINGS] ; Start of RDS setup logical group
RDS_ON_OFF={ Off, On }
ADD_RDS_TO_AUX_MPX={ Off, On }
RDS_LEVEL={Off , -43.9dB, -43.8dB , .. , -31.5dB, .. , -20.1dB , -20.0dB }
RDS_LEVEL={0.000Vpp , 0.005Vpp , 0.010Vpp, .. , 1.195Vpp , 1.200Vpp }
1
RDS_PHASE={-120Deg , -119Deg , .. , +0Deg , .. , +119Deg , +120Deg }
RDS_MODE={Uecp_Compatible, Uecp_Extended }
RDS_SYNC={Internal , External}
ACTIVE_DATASET={DataSet_1 , DataSet_2 , DataSet_3 , DataSet_4 , DataSet_5 , DataSet_6 }
ALTERNATIVE_DATASET={ DataSet_1,DataSet_2,DataSet_3,DataSet_4,DataSet_5,DataSet_6 }
ALTERNATIVE_DATASET_ON={Uecp_Command , External_Input_1 , .. , External_Input_5}
PS_CHARACTER_CODE_TABLE_SELECT={ No_Control_Characters , Ebu_Latin_Based ,
Ebu_Common_Core, Iso_646}
LANGUAGE_CODE_TABLE_SELECT={ Latin_1 , Latin_2 , Cyrillic , Greek , Turkish ,
Nordic_Languages }
TA_CONTROL_GROUP_SPACING={ 0 , 1 , ... , 8 }
TA_CONTROL_ON_TRANSITION_GROUPS={ 0 , 1 , ... , 15 }
TA_CONTROL_OFF_TRANSITION_GROUPS={ 0 , 1 , ... , 15 }
EON_TA_CONTROL_GROUP_SPACING={ 0 , 1 , ... , 8 }
EON_TA_CONTROL_ON_TRANSITION_GROUPS={ 0 , 1 , ... , 15 }
EON_TA_CONTROL_OFF_TRANSITION_GROUPS={ 0 , 1 , ... , 15 }
[END_RDS_SETTINGS] ; End of RDS Setup logical group
[REAL_TIME_CLOCK] ; Start of RTC group
RDS_CT={Enabled , Disabled}
RDS_TIME_OFFSET={-12:00 , -11:30 , .. , +0:00 , .. , +11:30 , +12:00}
[END_REAL_TIME_CLOCK]
End Point(1)
2
[START_DATASET_1] ; Start of DataSet 1 commands group
[SERVICES_SETUP] ; Start of RDS Services group
GROUP_SEQUENCE= { 0A , 0B , 1A , 1B , 2A , 2B , 3A , 3B , 4B , 5A , 5B ,
6A , 6B , 7A , 7B , 8A , 8B , 9A , 9B , 10A, 10B , 11A ,
11B , 12A , 12B , 13A, 13B , 14A , 14B ,15B }
3
GROUP_1A_SLC_SEQUENCE={ 0 , 1 , 2 , 3 , 4 , 5 , 6 , 7 }
4
1
For Rds Only Targets (it replaces line above)
2
If configuration file ends at this point and RDS plug is
installed, a Warning message is displayed, as Dataset has not been defined. If RDS plug is not
present but further data have been entered (up to on e of the following End Point), these Data will
be discarded.
3
You may enter up to 64 groups, picked up from the listed ones (all except type 4A & 15A
groups).